Compressor won’t start • Compressor shuts down • High coolant volume • Water in air system • Excessive noise/vibration

Troubleshooting – Low system pressure

Probable Cause What to Do
Compressor running in
"Unload" Mode.
Press "UNLOAD/LOAD" button.
Controller off-line set point
too low.
Press "UNLOAD/STOP" button; set off-line
set point at a higher value
Dirty air filter element. Check filter condition. Replace as required.
Air leak. Check air system piping.
Moisture separator trap drain
stuck open.
Inspect and repair.
Inlet valve not fully open. Inspect and repair. Check control
system operation.
System demand exceeds
compressor delivery.
Install larger or an additional compressor.

Use the link list above to access more online information about the best ways to solve compressed air system challenges. If the problem you’re having isn’t listed, please email us so we can add it. Our expert staff and technicians welcome the opportunity to help you solve problems with your compressed air system.